724-853-4047

Client Portal
USMSLogo2
✕
  • Environmental Testing
Main
  • Home
  • Services
    • USP 797
    • USP 797 Monthly Surface Sample Program
    • USP Media & Supplies
    • Training & Competencies
    • Enverify™ Viable Surface Sampling Competency
    • Microbial Surface Cleanliness
    • Hazardous Drug (HD) Wipe Sampling
    • Legionella
    • Microbially Influenced Corrosion
    • Ultrapure & Medical Device Water Testing
    • Indoor Environmental Quality
    • Healthcare
  • Resources
    Forms & Documents
    Chain of Custody
    Sample Collection
    Media & Supplies Order Form
    Accreditation Certificates
    Equipment Rental Agreement
  • Equipment Rental
  • Articles
  • About Us
  • Contact
    • Careers
    • New Customers
    • Contact Us

Pore Correction

August 21, 2018

Viable bioaerosol sampling is based upon the principle of sieve impaction in which air is aspirated through the perforated head of a volumetric air sampler. The air stream, which contains viable particles, is directed onto the surface of an agar plate. After sample collection, the agar plate is incubated and the resultant colonies are counted and expressed as colony forming units (CFU) per cubic meter (m3) of air (CFU/m3). As the number of viable particles in the air increases, the probability of more than one particle entering the same hole (perforation) in the sampler head increases. Therefore, the number of CFUs that are counted requires a statistical correction. This correction is specific for each sampler and type of head and is referenced in the manufacturer’s user manual for the air sampler.

We recommend pore correction for all of our customers since USP <797> states that the manufacturers’ instructions must be followed when using air sampling equipment.

When customers provide the type of air sampler and the number of holes in the sampler head, U.S. Micro-Solutions will apply pore correction to the CFU count. The pore correction factor is the number that is added to the agar plate count to determine the total count for the sample. The pore correction factor typically comes into play at CFU counts greater than 15, so it will not affect the action levels for ISO 5 or ISO 7 areas.

Share

Related posts

May 1, 2026

Celebrating 30 Years of U.S. Micro‑Solutions and a Refreshed Brand Identity


Read more
January 6, 2026

PRESS RLEASE: Change of Ownership at U.S. Micro-Solutions, Inc.


Read more
July 31, 2024

Pharmacy500


Read more

Certified Excellence in Laboratory Testing

Let's Get Started

Contact us today to see how our expertise can help you!
Get in Touch!
Telephone: 724-853-4047
Fax: 724-853-4049

Hours of Operation:
Weekdays 8 AM – 4 PM
Saturday 8 AM – 12 PM
Sunday - Closed

*Closed all Major Holidays*

Mailing Address:
U.S. Micro-Solutions, Inc.
302 Unity Plaza
Latrobe, PA 15650

GPS Address:
U.S. Micro-Solutions, Inc.
302 Technology Way
Latrobe, PA 15650

Customer Satisfaction Survey

© 2026 US Micro Solutions. All Rights Reserved.

✕

Login

Lost your password?